Live Grid Telemetry LIVE TELEMETRY: All 4 UK Nations & 14 DNO Licence Areas Monitored
Sync: 15m
Scheduled 48 properties 📮 CR4
⏱️ Logged: 18 Nov 2026 at 11:31 pm GMT

UK Power Networks (South Eastern - SPN) — Merton (CR4) Power Cut

Locally Identified Impact Area: Merton (Postcode CR4) — UKPN INCD-420457-J

📊 Executive Incident Telemetry

SCADA Live Feed Active
⏱️ Target Re-Energisation (ETR)
19 Nov 2026 at 6:47 am GMT
Calculating...
Licensed Operator
UK Power Networks (South Eastern - SPN)
Greater London, Inner Sub-stations
Customers Off-Supply
48 properties
Underlying Feeder Block
Elapsed Blackout Time
1h 23m
Since 23:31 GMT
Target ETR Window
19 Nov 2026 at 6:47 am GMT
Subject to Safety Isolation
Engineering Classification
We've had to turn off power in your area so our engineers can safely carry out emergency repairs to the network.
Primary Feeder Event
Statutory Jurisdiction
Ofgem
SI 2015/699 Standards

🗳️ 1-Click Community Status Verification

Are you currently affected in Merton (CR4)? Help neighbours and DNO loggers verify ground truth.

0 Verified Reports
🔴 Off: 0% (0) 🟡 Flickering: 0% (0) 🟢 Restored: 0% (0)

🗺️ Live Incident Epicenter & Regional Surveillance

Centered on Merton (CR4) — Coordinates: 51.4042, -0.1581
💡 Use two fingers to pan or zoom the map. One finger scrolls the page.

Live Community Reports & Local Street Updates

Share what is happening at your UK postcode to help verify restoration progress for neighbours.

0 Verified Updates

No recent resident comments recorded for this specific location yet. Submit the first postcode update above.

Share this live UK outage status:

⚙️ Official 5-Stage Network Restoration Progression

⚡ 1. SCADA Trip
Feeder alarm logged
2. FDIR Switching
Remote sectionalising
3. Crew Dispatched
Engineers en route
4. Physical Repair
Jointing & excavation
5. Re-Energised
Full supply restored

🏙️ Regional Grid Matrix: Surrounding Towns & Districts in London

Comparative telemetry surveillance across neighbouring administrative zones.

8 Local Districts
District / City Est. Population Grid Status Affected Premises Action
📍 Merton (CR4)
THIS INCIDENT
200,503 Active Outage 48 properties Current
Croydon 370,432 5 Active 497 Check →
Enfield 331,058 4 Active 22 Check →
Camberwell 320,289 8 Active 505 Check →
Barnet 318,747 2 Active 366 Check →
Brent 316,883 9 Active 227 Check →
Lambeth 300,113 8 Active 127 Check →
Bromley 299,925 2 Active 27 Check →
Wandsworth 287,060 6 Active 317 Check →

Emergency Field Jointing, Telemetry Dispatch & High-Voltage Switching Protocol

Focus: Live Cable Jointing & Substation Generator Synchronization
Primary Substation Switchgear Team inspecting utility infrastructure in Merton (CR4)
Active technical deployment deployed for Merton (CR4): Switchgear replacement and circuit breaker insulation inspection. Primary Substation Switchgear Team

Direct response protocols for incident #12095 in Merton (CR4) have mobilized UK Power Networks (South Eastern - SPN) emergency jointing teams and field dispatch operatives. Upon pinpointing the physical fault coordinates—utilising acoustic cable listening devices or sheath fault bridge locators—civil excavators establish clean trench access down to the high-voltage cable bed while complying with the New Roads and Street Works Act (NRSWA) safety protocols.

Repairing underground 11kV trifurcating cable faults requires precision craftmanship: certified cable jointers strip charred semi-conductive screens, bevel insulation layers, install mechanical shear-bolt connectors, and encapsulate the finished repair within a resin-filled or heat-shrink joint sleeve rated to withstand 24kV dielectric test voltages. Concurrently, mobile diesel generating sets (ranging from 100 kVA to 500 kVA) are positioned at key distribution substations to restore critical feeder blocks while permanent repairs proceed.

Before re-energising the isolated section, engineers must conduct rigorous phased insulation resistance testing (5kV Megger testing) and verify phase rotation balance at local feeder pillars. The final step involves coordinated remote SCADA switching with the network control desk to close feeder circuit breakers and synchronize restored supplies with the National Energy System Operator (NESO) 50Hz grid frequency.

🛡️ Citizen Action & Electrical Safety Protocol

Essential safety procedures and statutory consumer protections for Merton (CR4).

⚡ Step 1: Fusebox Check

Consumer Unit & RCD Trip Verification

Check whether your main Consumer Unit (fusebox) has tripped. If the Residual Current Device (RCD) or an individual Miniature Circuit Breaker (MCB) is down, toggle it up. If street lighting and neighbouring homes are also unlit, the issue is on UK Power Networks (South Eastern - SPN)'s external 11kV/LV distribution grid, not your home wiring.

📞 Emergency Dispatch

Call 105 Free National Power Cut Line

Dial 105 free from any UK landline or mobile phone to connect directly to UK Power Networks (South Eastern - SPN)'s emergency control room. Report hazardous damaged lines, fallen wooden poles, or substation smoke. The line operates 24/7/365 across England, Scotland, and Wales.

🧊 Food Safety

Food Standards Agency (FSA) 4-Hour Rule

Keep refrigerator and freezer doors firmly closed. A standard unopened domestic fridge safely maintains food temperatures for 4 hours. A full unopened freezer will keep contents safe for up to 48 hours (24 hours if half full). Discard perishable dairy and poultry if fridge temperature exceeds 8°C for over 2 hours.

🛡️ Equipment Safety

Appliance Surge Isolation Protocol

Switch off sensitive electronic devices—including OLED televisions, desktop computers, heat pumps, and induction hobs—at the wall socket. When UK Power Networks (South Eastern - SPN) re-energizes the local circuit, momentary inductive inrush voltage spikes can damage sensitive microprocessors.

💷 Legal Rights

Ofgem £95 Compensation Eligibility

Under Ofgem Guaranteed Standards, if your electricity supply is interrupted for 12 continuous hours under normal weather conditions, you are legally owed £95 by UK Power Networks (South Eastern - SPN), plus £40 per additional 12-hour block (up to £360). In most cases, DNOs must credit your supplier within 10 working days.

🚨 Vulnerable Households

Priority Services Register (PSR) Support

If anyone in your household is of pensionable age, has a disability, is reliant on vital medical equipment (oxygen concentrators, kidney dialysis), or has an infant under 5, contact UK Power Networks (South Eastern - SPN) to request emergency backup power, warm facilities, or mobile welfare vans under PSR guidelines.

📶 Communications

Emergency 999 National Roaming & Wi-Fi Calling

If your primary mobile carrier (EE, O2, Vodafone, or Three) loses cellular coverage, emergency 999 calls will automatically national-roam onto whichever carrier mast has operational battery backup in your area. For standard calls, connect your handset to battery-backed Wi-Fi.

🔥 Life Safety

Gas Smell Safety: 0800 111 999

If you smell natural gas during a blackout, do NOT touch any light switches, do NOT light candles, and do NOT use doorbells. Extinguish open flames, open windows to ventilate, evacuate all occupants, and immediately call the National Gas Emergency Service free on 0800 111 999.